| Sign In | Join Free | My howtoaddlikebutton.com |
|
working temperature : -40℃~+105℃
Current Range : ±500A
Voltage - Supply : 5.5V~40V
Description : ±500A Current Sensors RoHS
Mfr. Part # : IVT-S-500-U0-I-CAN1-12/24
Model Number : IVT-S-500-U0-I-CAN1-12/24
The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive and industrial sectors. It features a modular design for flexibility and offers continuous current measurement up to 2500 A with automatic range extension for higher peak currents. Utilizing a shunt-based method with a 16-bit ADC, it communicates via a CAN 2.0a interface, supported by a CAN description file for easy integration.
| Parameter | Value | Unit | Notes |
| Continuous Current Measurement Range | 2500 | A | Automatic range extension for peaks |
| Measurement Method | Shunt-based | 16-bit ADC | |
| Communication Interface | CAN 2.0a | CAN description file (CAN-dbc) available | |
| Measurement Modes | Disable, Trigger, Cycle running | Configurable per channel | |
| Output Signals | Current, Voltage (3 channels), Temperature, Power, Current counter, Energy counter | A, V, C, W, As, Wh | Configurable output transfer rate and value |
| Internal Safety Features | Sensor status monitoring, Dual ADC for current verification, ADC reference voltage monitoring | Detects non-valid measurement conditions | |
| Log Data Storage | 15-minute intervals (if in run-mode) | Recoverable on sensor reset | |
| Galvanic Isolation | Max Working Isolation Voltage: 1000V RMS (CATI), 600V RMS (CATII), 300V RMS (CATIII) | V RMS | Basis Isolation DC Voltage: 1000 V, Reinforced Isolation DC Voltage: 600 V |
| Highest allowed transient overvoltage | 6000 | V | (for 1s) |
| Minimum External Clearance distance | > 40 | mm | |
| Minimum External Creepage distance | > 50 | mm | |
| Minimum Internal Clearance | 8 | mm | |
| Flammability Rating | UL94-V0 | For Housing, Connectors, PCB | |
| Sampling Rate (Current) | 1 | ms | Max output rate |
| Sampling Rate (Voltage) | 2, 5, 10 | ms | Multiplexed on ADC2 |
|
|